blob: 8f770e8d591787184754847a75194c0ef3a43fde [file] [log] [blame]
OpenROAD 79a46b62da64bbebc18f06b20c42211046de719a
This program is licensed under the BSD-3 license. See the LICENSE file for details.
Components of this program may be licensed under more restrictive licenses which must be honored.
[INFO ODB-0222] Reading LEF file: /home/serdar/Desktop/openram_demo/openram_openmpw/openlane/user_project_wrapper/runs/user_project_wrapper/tmp/merged.unpadded.nom.lef
[INFO ODB-0223] Created 13 technology layers
[INFO ODB-0224] Created 25 technology vias
[INFO ODB-0225] Created 442 library cells
[INFO ODB-0226] Finished LEF file: /home/serdar/Desktop/openram_demo/openram_openmpw/openlane/user_project_wrapper/runs/user_project_wrapper/tmp/merged.unpadded.nom.lef
[INFO ODB-0127] Reading DEF file: /home/serdar/Desktop/openram_demo/openram_openmpw/openlane/user_project_wrapper/runs/user_project_wrapper/results/floorplan/user_project_wrapper.def
[INFO ODB-0128] Design: user_project_wrapper
[INFO ODB-0094] Created 100000 Insts
[INFO ODB-0130] Created 637 pins.
[INFO ODB-0131] Created 131843 components and 273756 component-terminals.
[INFO ODB-0133] Created 1044 nets and 1397 connections.
[INFO ODB-0134] Finished DEF file: /home/serdar/Desktop/openram_demo/openram_openmpw/openlane/user_project_wrapper/runs/user_project_wrapper/results/floorplan/user_project_wrapper.def
[INFO PDN-0001] Inserting grid: stdcell_grid
[INFO PDN-0001] Inserting grid: macro - SRAM0
[INFO PDN-0001] Inserting grid: macro - SRAM1
[INFO PDN-0001] Inserting grid: macro - SRAM2
[INFO PDN-0001] Inserting grid: macro - SRAM3
[WARNING PDN-0110] No via inserted between met4 and met5 at (638.9700, 826.5400) - (642.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (818.9700, 826.5400) - (822.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (998.9700, 826.5400) - (1002.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (1178.9700, 826.5400) - (1182.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (1718.9700, 826.5400) - (1722.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (1898.9700, 826.5400) - (1902.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (2078.9700, 826.5400) - (2082.0700, 827.4300) on vdda1
[WARNING PDN-0110] No via inserted between met4 and met5 at (2258.9700, 826.5400) - (2262.0700, 827.4300) on vdda1
[WARNING PSM-0016] Voltage pad location (VSRC) file not specified, defaulting pad location to checkerboard pattern on core area.
[WARNING PSM-0017] X direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0018] Y direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0019] Voltage on net vccd1 is not explicitly set.
[WARNING PSM-0022] Using voltage 1.800V for VDD network.
[WARNING PSM-0065] VSRC location not specified, using default checkerboard pattern with one VDD every size bumps in x-direction and one in two bumps in the y-direction
[WARNING PSM-0030] VSRC location at (845.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 15.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 15.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 555.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 555.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 555.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 735.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 735.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 735.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1095.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1095.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 1275.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 915.880um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (910.520um, 915.880um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 1.800.
[WARNING PSM-0030] VSRC location at (1685.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 915.880um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (1630.520um, 915.880um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 1.800.
[WARNING PSM-0030] VSRC location at (285.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 1455.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 1455.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 1455.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 1455.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2535.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2535.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 3255.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 3255.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 3255.880um).
[INFO PSM-0031] Number of PDN nodes on net vccd1 = 373289.
[INFO PSM-0064] Number of voltage sources = 88.
[INFO PSM-0040] All PDN stripes on net vccd1 are connected.
[WARNING PSM-0016] Voltage pad location (VSRC) file not specified, defaulting pad location to checkerboard pattern on core area.
[WARNING PSM-0017] X direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0018] Y direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0019] Voltage on net vssd1 is not explicitly set.
[WARNING PSM-0021] Using voltage 0.000V for ground network.
[WARNING PSM-0065] VSRC location not specified, using default checkerboard pattern with one VDD every size bumps in x-direction and one in two bumps in the y-direction
[WARNING PSM-0030] VSRC location at (5.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, -9.470um).
[WARNING PSM-0030] VSRC location at (845.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, -9.470um).
[WARNING PSM-0030] VSRC location at (1685.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, -9.470um).
[WARNING PSM-0030] VSRC location at (2525.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, -9.470um).
[WARNING PSM-0030] VSRC location at (285.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2193.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 398.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 218.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 398.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 578.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 218.380um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (1113.020um, 218.380um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 0.000.
[WARNING PSM-0030] VSRC location at (1965.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 578.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 578.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 758.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 758.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2280.870um, 758.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 938.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 938.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 1118.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 1118.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2280.870um, 1118.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 1298.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 938.380um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (933.020um, 938.380um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 0.000.
[WARNING PSM-0030] VSRC location at (1685.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 938.380um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (1653.020um, 938.380um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 0.000.
[WARNING PSM-0030] VSRC location at (2525.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 1298.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 1478.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 1658.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 1478.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 1478.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 1478.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 1478.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2280.870um, 1478.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 1658.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 1658.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 1658.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 1658.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 1838.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 1838.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 1838.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 1838.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 2018.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 2018.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2193.020um, 2018.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 2198.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 2198.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 2378.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 2378.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2193.020um, 2378.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 2558.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 2558.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 2558.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 2558.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2193.020um, 2738.380um).
[WARNING PSM-0030] VSRC location at (5.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (-14.830um, 2918.380um).
[WARNING PSM-0030] VSRC location at (845.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (933.020um, 2918.380um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1653.020um, 2918.380um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2553.020um, 2918.380um).
[WARNING PSM-0030] VSRC location at (285.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (213.020um, 3098.380um).
[WARNING PSM-0030] VSRC location at (1125.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1113.020um, 3098.380um).
[WARNING PSM-0030] VSRC location at (1965.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2013.020um, 3098.380um).
[WARNING PSM-0030] VSRC location at (2805.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2733.020um, 3098.380um).
[WARNING PSM-0030] VSRC location at (565.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (573.020um, 3278.380um).
[WARNING PSM-0030] VSRC location at (1405.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1473.020um, 3278.380um).
[WARNING PSM-0030] VSRC location at (2245.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2193.020um, 3278.380um).
[INFO PSM-0031] Number of PDN nodes on net vssd1 = 374256.
[INFO PSM-0064] Number of voltage sources = 88.
[INFO PSM-0040] All PDN stripes on net vssd1 are connected.
[INFO]: Setting RC values...
[INFO PSM-0002] Output voltage file is specified as: /home/serdar/Desktop/openram_demo/openram_openmpw/openlane/user_project_wrapper/runs/user_project_wrapper/tmp/floorplan/7-pdn.pga.rpt.
[WARNING PSM-0016] Voltage pad location (VSRC) file not specified, defaulting pad location to checkerboard pattern on core area.
[WARNING PSM-0017] X direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0018] Y direction bump pitch is not specified, defaulting to 140um.
[WARNING PSM-0019] Voltage on net vccd1 is not explicitly set.
[WARNING PSM-0022] Using voltage 1.800V for VDD network.
[WARNING PSM-0065] VSRC location not specified, using default checkerboard pattern with one VDD every size bumps in x-direction and one in two bumps in the y-direction
[WARNING PSM-0030] VSRC location at (845.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 15.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 10.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 15.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 150.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 195.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 290.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 430.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 555.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 375.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 555.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 570.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 555.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 735.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 735.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 710.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 735.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 850.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 990.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 915.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1095.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1095.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1130.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 1275.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 915.880um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (910.520um, 915.880um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 1.800.
[WARNING PSM-0030] VSRC location at (1685.520um, 1270.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 915.880um).
[WARNING PSM-0067] Multiple voltage supply values mappedat the same node (1630.520um, 915.880um).If you provided a vsrc file. Check for duplicate entries.Choosing voltage value 1.800.
[WARNING PSM-0030] VSRC location at (285.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 1455.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1941.550um, 1455.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1410.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 1455.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1550.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2277.470um, 1455.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 1690.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 1635.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 1830.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 1815.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 1970.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 1995.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2110.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2250.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 2175.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2390.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 2355.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2535.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2530.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2535.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 2670.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 2715.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 2810.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (5.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (10.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (845.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (910.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (1685.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1630.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (2525.520um, 2950.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2530.520um, 2895.880um).
[WARNING PSM-0030] VSRC location at (285.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (370.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (1125.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1090.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (1965.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1990.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (2805.520um, 3090.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2890.520um, 3075.880um).
[WARNING PSM-0030] VSRC location at (565.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (550.520um, 3255.880um).
[WARNING PSM-0030] VSRC location at (1405.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (1450.520um, 3255.880um).
[WARNING PSM-0030] VSRC location at (2245.520um, 3230.880um) and size 10.000um, is not located on an existing power stripe node. Moving to closest node at (2170.520um, 3255.880um).
[INFO PSM-0031] Number of PDN nodes on net vccd1 = 373289.
[WARNING PSM-0071] Instance _150_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _151_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _152_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _153_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _154_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _155_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _156_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _157_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _158_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _159_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _160_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _161_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _162_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _163_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _164_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _165_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _166_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _167_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _168_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _169_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _170_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _171_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _172_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _173_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _174_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _175_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _176_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _177_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _178_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _179_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _180_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _181_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _182_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _183_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _184_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _185_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _186_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _187_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _188_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _189_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _190_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _191_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _192_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _193_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _194_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _195_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _196_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _197_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _198_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _199_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _200_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _201_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _202_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _203_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _204_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _205_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _206_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _207_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _208_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _209_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _210_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _211_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _212_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _213_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _214_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _215_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _216_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _217_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _218_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _219_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _220_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _221_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _222_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _223_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _224_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _225_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _226_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _227_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _228_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _229_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _230_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _231_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _232_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _233_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _234_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _235_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _236_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _237_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _238_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _239_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _240_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _241_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _242_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _243_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _244_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _245_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _246_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _247_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _248_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _249_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _250_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _251_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _252_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _253_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _254_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _255_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _256_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _257_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _258_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _259_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _260_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _261_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _262_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _263_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _264_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _265_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _266_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _267_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _268_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _269_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _270_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _271_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _272_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _273_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _274_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _275_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _276_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _277_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _278_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _279_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _280_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _281_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _282_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _283_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _284_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _285_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _286_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _287_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _288_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _289_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _290_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _291_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _292_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _293_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _294_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _295_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _296_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _297_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _298_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _299_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _300_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _301_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _302_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _303_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _304_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _305_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _306_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _307_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _308_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _309_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _310_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _311_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _312_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _313_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _314_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _315_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _316_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _317_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _318_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _319_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _320_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _321_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _322_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _323_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _324_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _325_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _326_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _327_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _328_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _329_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _330_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _331_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _332_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _333_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _334_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _335_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _336_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _337_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _338_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _339_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _340_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _341_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _342_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _343_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _344_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _345_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _346_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _347_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _348_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _349_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _350_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _351_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _352_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _353_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _354_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _355_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _356_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _357_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _358_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _359_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _360_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _361_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _362_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _363_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _364_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _365_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _366_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _367_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _368_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _369_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _370_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _371_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _372_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _373_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _374_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _375_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _376_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _377_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _378_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _379_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _380_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _381_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _382_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _383_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _384_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _385_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _386_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _387_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _388_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _389_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _390_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _391_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _392_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _393_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _394_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _395_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _396_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _397_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _398_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _399_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _400_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _401_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _402_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _403_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _404_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _405_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _406_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _407_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _408_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _409_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _410_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _411_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _412_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _413_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _414_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _415_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _416_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _417_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _418_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _419_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _420_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _421_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _422_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _423_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _424_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _425_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _426_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _427_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _428_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _429_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _430_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _431_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _432_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _433_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _434_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _435_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _436_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _437_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _438_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _439_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _440_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _441_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _442_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _443_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _444_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _445_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _446_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _447_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _448_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _449_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _450_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _451_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _452_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _453_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _454_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _455_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _456_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _457_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _458_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _459_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _460_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _461_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _462_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _463_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _464_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _465_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _466_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _467_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _468_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _469_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _470_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _471_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _472_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _473_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _474_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _475_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _476_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _477_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _478_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _479_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _480_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _481_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _482_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _483_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _484_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _485_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _486_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _487_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _488_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _489_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _490_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _491_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _492_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _493_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _494_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _495_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _496_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _497_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _498_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _499_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _500_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _501_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _502_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _503_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _504_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _505_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _506_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _507_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _508_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _509_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _510_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _511_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _512_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _513_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _514_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _515_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _516_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _517_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _518_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _519_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _520_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _521_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _522_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _523_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _524_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _525_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _526_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _527_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _528_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _529_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _530_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _531_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _532_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _533_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _534_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _535_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _536_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _537_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _538_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _539_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[WARNING PSM-0071] Instance _540_ is not placed. Therefore, the power drawn by this instance is not considered for IR drop estimation. Please run analyze_power_grid after instances are placed.
[INFO PSM-0064] Number of voltage sources = 88.
[INFO PSM-0040] All PDN stripes on net vccd1 are connected.
########## IR report #################
Worstcase voltage: 1.80e+00 V
Average IR drop : 6.44e-11 V
Worstcase IR drop: 1.04e-09 V
######################################