Wojciech Gryncewicz | 9039be3 | 2020-11-06 14:05:33 +0100 | [diff] [blame] | 1 | Name,Description,Flags,Value,Unit |
| 2 | (via2.X.1),Via2 connects met2 to met3 in the SKY130T*/SKY130P*/SP8Q/SP8P* flow and met2/capm to met3 in the SKY130DI* flow.,,, |
| 3 | (via2.1a),Min and max L and W of via2 (except for rule via2.1b/1c/1d/1e/1f),AL,0.200,µm |
| 4 | (via2.1b),"Three sizes of square Vias allowed inside areaid:mt: 0.280um, 1.2 um and 1.5 um",AL,N/A,N/A |
| 5 | (via2.1c),Two sizes of square Vias allowed inside areaid:mt: 1.2 um and 1.5 um,AL,N/A,N/A |
| 6 | (via2.1d),"Four sizes of square Vias allowed inside areaid:mt: 0.2um, 0.280um, 1.2 um and 1.5 um",AL,, |
| 7 | (via2.1e),"Three sizes of square Vias allowed inside areaid:mt: 0.8um, 1.2 um and 1.5 um",AL,N/A,N/A |
| 8 | (via2.1f),Two sizes of square Vias allowed outside areaid:mt: 0.8um and 1.2 um,AL,N/A,N/A |
| 9 | (via2.2),Spacing of via2 to via2,AL,0.200,µm |
| 10 | (via2.3),Only min. square via2s are allowed except die seal ring where via2s are (Via2 CD)*L,AL,0.2*L, |
| 11 | (via2.4),Via2 must be enclosed by Met2 by at least …,AL,0.040,µm |
| 12 | (via2.4a),"Inside :drc_tag:`areaid.mt`, 1.5 µm Via2 must be enclosed by met2 by atleast",,0.140,µm |
| 13 | (via2.5),Via2 must be enclosed by Met2 on one of two adjacent sides by at least …,AL,0.085,µm |
| 14 | (via2.11),Min and max L and W of via2,CU,0.210,µm |
| 15 | (via2.12),Min spacing between via2's,CU,0.180,µm |
| 16 | (via2.13),Min spacing between via2 rows,CU,0.200,µm |
| 17 | (via2.14),Via2 must be enclosed by met2 by atleast,CU,0.035,µm |
| 18 | (via2.irdrop.1),"For 1 <= n <= 2 via2's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.0,µm |
| 19 | (via2.irdrop.2),"For 3 <= n <= 4 via2's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.6,µm |
| 20 | (via2.irdrop.3),"For 5 <= n <= 30 via2's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.79,µm |
| 21 | (via2.irdrop.4),"For n > 30 via2's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.9,µm |