blob: c8c96969e7ce7187ac22deeaa702c4ce7eb610e1 [file] [log] [blame]
Wojciech Gryncewicz9039be32020-11-06 14:05:33 +01001Name,Description,Flags,Value,Unit
2(ct.1),Min and max L and W of mcon,DNF,0.170m
3(ct.2),Spacing of mcon to mcon,DNF,0.190m
4(ct.3),Only min. square mcons are allowed except die seal ring where mcons are…,,0.170*L,
5(ct.4),Mcon must be enclosed by LI by at least …,P,0.000m
6(ct.irdrop.1),"For 1 <= n <= 10 contacts on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.2m
7(ct.irdrop.2),"For 11 <= n <= 100 contacts on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.3m
8(ct.irdrop.3),"For n > 100 contacts on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…",CU IR,0.7m