| Parasitic Layout Extraction | |
| =========================== | |
| This table list layers and contacts included in SPICE models, and parasitic layers include in the AssuraLayout Extraction. | |
| The modeled columns indicate sheets and contacts that are parasitic resistance/capacitance included in the model extraction measurements. | |
| The CAD columns indicate sheets and contacts that are parasitics included in the schematic/layout RCX from Assura. | |
| .. csv-table:: Parasitic Extraction Table | |
| :file: rcx/rcx-all.tsv | |
| :header-rows: 2 | |
| :stub-columns: 1 | |
| :delim: U+0009 | |
| .. note:: The models includes M1/M2 capacitance. As a result of RCX extraction limitation M1/M2 routing over the varactor will have no capacitance extraction. | |
| Routing and placement of devices over or under Precision resistors (xhrpoly_X_X) should be avoided. | |
| The parasitic capacitance between 3-terminal MIMC and any routing/devices is not included in layout RCX, except M3 by 1 snap grid width. | |
| No artificial fringing capacitance is extracted for MIMC M2/M3 due to CAD algorithm after CAPM sizing. | |
| The parasitic capacitance between Precision resistors (xhrpoly_X_X) and any routing/devices is not included in layout RCX. | |
| S8Q-5R is not supported for RF ESD diode RCX blocking. | |
| The ``areaid:substratecut`` will be extracted as a 0.123 ohm two terms resistor. | |
| Resistance Rules | |
| ---------------- | |
| .. todo:: This table should be rendered like the periphery rules. | |
| .. csv-table:: Table of resistance rules | |
| :file: rcx/resistance-rules.csv | |
| :stub-columns: 1 | |
| Resistance Values | |
| ----------------- | |
| This section includes tables of basic resistance values for SKY130. | |
| Further data can be found in the `"SKY130 Stackup Capacitance Data" spreadsheet`_. | |
| .. csv-table:: Table - Resistances | |
| :file: rcx/resistance-values.tsv | |
| :header-rows: 1 | |
| :delim: U+0009 | |
| Capacitance Rules | |
| ----------------- | |
| .. todo:: This table should be rendered like the periphery rules. | |
| .. csv-table:: Table of capacitance rules | |
| :file: rcx/capacitance-rules.csv | |
| :stub-columns: 1 | |
| Capacitance Values | |
| ------------------ | |
| This section includes tables of basic capacitance values for SKY130. | |
| Further data can be found in the `"SKY130 Stackup Capacitance Data" spreadsheet`_. | |
| .. _"SKY130 Stackup Capacitance Data" spreadsheet: https://docs.google.com/spreadsheets/d/1N9To-xTiA7FLfQ1SNzWKe-wMckFEXVE9WPkPPjYkaxE/edit#gid=226894802 | |
| Basic Capacitance - Fringe Downward | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Fringe capacitances are a constant value per unit length and are approximations. Determined by creating a layout with a 5um x 10um rectangle of each layer over or under a much larger rectangle of the other layer. The fringe capacitance computed from the total given minus the parallel plate capacitance. | |
| "downward direction" means that the larger plate is below the 5um x 10um plate. | |
| The layer in the first column is always the layer with the 5um x 10um plate. | |
| .. csv-table:: Table - Capacitance - Fringe Downward | |
| :file: rcx/capacitance-fringe-downward.tsv | |
| :header-rows: 1 | |
| :delim: U+0009 | |
| Basic Capacitance - Fringe Upward | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Fringe capacitances are a constant value per unit length and are approximations. Determined by creating a layout with a 5um x 10um rectangle of each layer over or under a much larger rectangle of the other layer. The fringe capacitance computed from the total given minus the parallel plate capacitance. | |
| "upward direction" means that the larger plate is above the 5um x 10um plate. | |
| The layer in the first column is always the layer with the 5um x 10um plate. | |
| .. csv-table:: Table - Capacitance - Fringe Upward | |
| :file: rcx/capacitance-fringe-upward.tsv | |
| :header-rows: 1 | |
| :delim: U+0009 | |
| Basic Capacitance - Parallel | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| .. csv-table:: Table - Capacitance - Parallel | |
| :file: rcx/capacitance-parallel.tsv | |
| :header-rows: 1 | |
| :delim: U+0009 | |
| Discrepencies | |
| ------------- | |
| Non-precision poly resistors | |
| These resistors do not extract capacitance to substrate. | |
| This needs to be accounted for manually by using ICPS_0150_0210 (cap per perimeter), and ICPS_2000_4000 (cap per area). | |
| Un-shielded VPP's | |
| Any routing above an un-shielded VPP will not be extracted. | |
| The impact of this on total capacitance and parasitic capacitance is already comprehended in the model corners, however, cross-talk is not modeled. Also, parasitic cap is routed to ground and this may not be ideal for the scenario. | |
| The parasitic cap can be estimated using RescapWeb. | |