Name,Description,Flags,Value
(pwres.1.-),Pwell resistor has to be enclosed by the res layer,NC,
(pwres.2.-),Min/Max width of pwell resistor,,2.650
(pwres.3.-),Min length of pwell resistor,,26.500
(pwres.4.-),Max length of pwell resistor,,265.00
(pwres.5.-),Min/Max spacing of tap inside the pwell resistor to nwell,,0.220
(pwres.6.-),Min/Max width of tap inside the pwell resistor,,0.530
(pwres.7a.-),Every pwres_terminal must enclose 12 licon1,,
(pwres.7b.-),Every pwres_terminal must enclose 12 mcons if routed through metal1,,
(pwres.8.-),Diff or poly is not allowed in the pwell resistor.,,
(pwres.9.-),Nwell surrounding the pwell resistor must have a full ring of contacted tap strapped with metal.,,
(pwres.10.-),The res layer must abut pwres_terminal on opposite and parallel edges,,