7.5 Poly2
---------
.. csv-table:: Poly2 RULES
:file: tables_clear/7.5_poly.csv
:widths: 200, 700, 100
:align: center
.. note::
1. Parasitic capacitances need to be considered when adding dummy poly2. Customer has the option to use
GLOBALFOUNDRIES's dummy poly2 generation rule. In this case, customer needs to mark out areas of
circuit which are sensitive to parasitic capacitance and do not want dummy poly2 fill generated. Customer
need to separate circuit Metal1 and Metal2 from dummy metal in order that dummy Poly2 can be generated
beneath dummy metal. Refer to 4.1 for layer name.
.. image:: images/pol2.png
:width: 800
:align: center
:alt: poly2