blob: 25fedbb94f4fdd1f2eb32dc2602cddf0c864e96e [file] [log] [blame]
RULE NO.,DESCRIPTION,LV,MV,Comment
LU.1,"FOR LV and MV inside DNWELL
This rule is to check Max. Nwell/DNWELL tap space to every
point on the boundary of PCOMP inside Nwell/DNWELL.
For within 50um from (the PCOMP inside NWELL or DNWELL),
minimum LVPWELL to (PCOMP outside LVPWELL) space is
defined as (x):",,,
,"a\) If x >= 2.0um, then max Nwell/DNWELL tap space to every
Point on the boundary of PCOMP inside NWELL/DNWELL",50,15,Rule
,"b\) If x >= 1.0um and < 2um, then max Nwell/DNWELL tap space to
every point on the boundary of PCOMP inside NWELL/DNWELL",30,15,Rule
,"c\) If x < 1.0um, then max Nwell/DNWELL tap space to every
point on the boundary of PCOMP inside NWELL/DNWELL",15,15,Rule
LU.2,"FOR LV and MV inside DNWELL
This rule is to check Max. LVPWELL tap space to every point on
the boundary of NCOMP inside LVPWELL.
For within 50um from (the NCOMP inside LVPWELL), minimum
LVPWELL to (PCOMP outside LVPWELL) space is defined as x:",,,
,"a\) If x >= 2.0um, then Max. LVPWELL tap space to every point on
the boundary of NCOMP inside LVPWELL.",50,15,Rule
,"b\) If x >= 1.0um and < 2um, then Max. LVPWELL tap space to
every point on the boundary of NCOMP inside LVPWELL.",30,15,Rule
,"c\) If x <1.0um, then Max. LVPWELL tap space to every point on
the boundary of NCOMP inside LVPWELL.",15,15,Rule
LU.3,"FOR LV and MV outside DNWELL
This rule is to check Max. LVPWELL (Psub) tap outside
DNWELL space to every point on the boundary of NCOMP
outside NWELL/DNWELL.
For within 50um from the (NCOMP in LVPWELL or Psub),
Minimum NWELL to (NCOMP outside Nwell) space is defined as y.",,,
,"a\) If y >= 2.0um, then Max. LVPWELL (Psub) tap outside
DNWELL space to every point on the boundary of NCOMP
outside NWELL/DNWELL.",50,15,Rule
,"b\) If y >= 1.0um and < 2.0um, then Max. LVPWELL (Psub) tap
outside DNWELL space to every point on the boundary of
NCOMP outside NWELL/DNWELL.",30,15,Rule
,"c\) If y <1.0um, then Max. LVPWELL (Psub) tap outside
DNWELL space to every point on the boundary of NCOMP
outside NWELL/DNWELL.",15,15,Rule
LU.4,"FOR LV and MV outside DNWELL
This rule is to check Max. Nwell tap space to every point on the
boundary of PCOMP inside Nwell.
For within 50um from (the PCOMP inside NWELL), minimum
NWELL to (NCOMP outside Nwell) space is defined as y:",,,
,"a\) If y >= 2.0um, then Max. Nwell tap space to every point on the
boundary of PCOMP inside Nwell",50,15,Rule
,"b\) If y >= 1.0um and < 2um, then Max. Nwell tap space to every
point on the boundary of PCOMP inside Nwell",30,15,Rule
,"c\) If y < 1.0um, then Max. Nwell tap space to every point on the
boundary of PCOMP inside Nwell",15,15,Rule
,For Native Vt NMOS (check for NAT marking),,,
LU.5,"For within 50um from NAT layer, If there is NWELL present, then
NAT layer shall be directly surrounded by PCOMP substrate guard
ring. (No other NCOMP, NWELL in between the NAT and
PCOMP guard ring)",,,Rule
,Common Guidelines,,,
LU.7*,Maximize the number of contacts in the substrate and well taps.,--,--,Guideline
,"Total equivalent contact area to the channel area generating
substrate current (Poly2 intersecting COMP) should be more than
3%. This is a guideline only.",,,
LU.8*,"Butted substrate contact to source is always the best for latch-up
immunity wherever possible",--,--,Guideline
LU.9*,"All Nwell taps shall be connected to respective most highest
Potential",--,--,Guideline
LU.10*,All Psub shall be connected to their respective lowest potential,--,--,Guideline