Mega-Project Counter Tests
The directory includes three tests for the counter mega-project example:
IO Ports Test:
- Configures the Mega-project lower 8 IO pins as outputs
- Observes the counter value through the configured pins in the testbench
Logic Analyzer Test 1:
- Configures LA probes [31:0] as inputs to the management SoC to monitor the counter value
- Configures LA probes [63:32] as outputs from the management SoC to set the counter initial value
- Flags when counter value exceeds 500 through the management SoC gpio
- Outputs message to the UART when the test concludes successfuly
Logic Analyzer Test 2:
- Configures LA probes [64] and [65] as outputs from the management SoC to set counter clock and reset values
- Provides counter clock and monitors the counter value after five clock cycles